Laboratory Management

What Is Sample Accessioning in a Laboratory? Process, Steps, Benefits & Automation

MargLabz Team··10 min read
What Is Sample Accessioning in a Laboratory? Process, Steps, Benefits & Automation
Key takeaways

Sample accessioning is the process of receiving a specimen, verifying its identity and condition, registering it and assigning a unique accession number so it can be traced through testing and reporting. It joins the physical tube to its digital record, and mistakes made here carry through to the report. Barcodes and a configured LIS reduce manual entry, but staff must still verify each tube and apply written acceptance criteria.

On Monday at 8:30 in the morning, a courier arrives at the reference lab of a city with a package containing samples collected from five different collection sites. Some of these samples have printed bar codes; others have names written by hand. One requisition is so badly smudged that it cannot be read. What happens to the samples in the next 20 minutes will determine if the patients receive the correct report on time. This initial step of processing the samples is called "sample accessioning".

Mistakes committed in this area seldom remain at the reception desk. An incorrect patient identification, a missing test, or a tube that has been entered one hour after being received will travel with the sample into the analytical instrument and ultimately onto the final report. This document describes what sample accessioning is, how the procedure occurs on a step-by-step basis, the purpose of an accession number, and how laboratory software assists.

What Is Sample Accessioning?

Sample accessioning involves the receipt of a specimen, verification of both identity and condition of the specimen, recording the specimen into the laboratory's record system, and providing the specimen with a unique identification number (accession number) for tracking during the testing and reporting processes.

In reality, accessioning connects two separate entities that must remain connected: the physical sample (tube) and the electronic record of the sample. All subsequent steps in the process, including the creation of a work list, the analysis of the sample, and the signing off on a report, depend upon this connection. Without being able to confidently match each individual tube with a single patient, a single order, and a single record, then regardless of how accurate or precise the testing may have been, the laboratory will not be able to justify or support the validity of the results.

Why Is Sample Accessioning Important in Diagnostic Laboratories?

The accessioning process is the initial step for a laboratory to formally check off the sample being processed and therefore provides an additional layer of security for all subsequent processes.

  • Correct patient identification: you must correctly associate the correct patient with the correct tube prior to beginning the test.
  • Fewer registration mistakes (errors): the cost of correcting those made at the time of entry can be reduced significantly. Mistakes in matching tubes with requisitions, and bills with either or both, can be identified before they become costly to correct.
  • Traceability: Every single sample is documented with a chronological record of who accepted it, at what time, and what state it was in.
  • Samples are routed directly to hematology, biochemistry, or microbiology without the need for searching.
  • The recorded receipt time will show you when there are delays. For example, CDC's guidelines for the CLIA quality system require that all laboratory facilities record the date and time each specimen is received.
  • The use of a single standard for receiving and processing each branch and franchise's intake procedures provides all branches and franchises with consistent guidelines.
  • Accountability: Every time someone accepts or rejects a document, there is an individual with a name and a date/time stamp associated with that decision.

How Does the Sample Accessioning Process Work? Step by Step

Eleven steps are included in a proper workflow, although each laboratory has a slightly different order.

  1. Sample receipt. A receipt is provided for samples received by the laboratory. Laboratory staff collect samples from patients who visit the laboratory, home collection phlebotomists who have collected samples at patient homes, and sample collection boxes delivered to the laboratory via couriers. Errors include samples being left in a box without being logged.
  2. Identity Verification. Validate that the name, age or some other identification value listed on the tube matches what is displayed in either the requisition or bill. The CDC has provided guidance regarding CLIA-regulated testing and states that there should be at least two forms of patient identification listed on each sample. Example: A label that contains only the patient's first name.
  3. Match with the requisition. Verify that each tube is ordered and that all of those tubes are included in that order. Error: there are either too many or not enough tubes for a profile.
  4. Check your samples for the proper container, type of sample, amount, and quality. Do you have serum in a standard blood tube, or do you have EDTA blood for a complete blood count (CBC)? Is there a sufficient quantity of the sample and does it show signs of being hemolyzed or leaking? Error: The correct container was not used for the requested test.
  5. The next step is to apply the acceptance/rejection criteria. Then, compare the sample you have collected with your written standard operating procedures (SOP). The Centers for Disease Control and Prevention (CDC) list many of the most common reasons why samples may be rejected, including leakage, an inadequate quantity of material, collecting the wrong type of sample, labeling the sample incorrectly, storing/transporting the sample at the incorrect temperature, and experiencing delays in transporting the sample. Error: Accepting a questionable sample "just this once".
  6. Register the sample in the computer system. At that time, enter the date/time received, the originating branch/physician's office, and other relevant information about the sample into the laboratory information system (LIS) or registration document. Delay in registering the sample results in an inaccurate representation of the turnaround time.
  7. Create a distinct accession number. The system, or a controlled log, provides the number. Error: two samples have been given the same number.
  8. The barcode label can be printed or attached. It must go onto the proper tube. Error: The correct label was placed on the wrong tube.
  9. Assigning tests and priorities. as well as linking requested tests to the order, indicating if a sample is "STAT" or urgent, and noting whether it requires a fast or a timed collection. An error occurred when a package was ordered, however, one of the components within that package was not mapped.
  10. Route to the department. Send the tube to the correct bench, referral queue, or an outsourced partner. Error: a sample that arrives at the incorrect department.
  11. Maintain current status and follow the path of your samples. All movements of a sample will be documented for anyone who wishes to determine its location. However, if you update the status of your sample too late or do not update it at all, this is an error.

Receiving personnel or a designated accessioner typically perform steps one through eight of the process; however, if there are exceptions, they are processed by a senior technologist. The division of work will vary based on the size of the laboratory.

What Is a Sample Accession Number?

A typical example of an accession number is a unique identification code that laboratories assign to incoming specimens to allow for easy identification of the specimen's records, to track each individual specimen, and to prevent confusion between different specimens.

Each patient's unique identification number (which is assigned when a patient first receives care) remains associated with the individual regardless of how many times they receive care. Each order/bill has a separate unique identification number that applies to only one visit. One order may result in multiple tubes, each of which will have a unique sample ID/accession number. The format of the unique identification number varies based on what type of laboratory is using it and how its computer systems are configured. Some laboratories utilize consecutive numbering, while others utilize the date of service and/or location of the facility as part of the unique identification number.

Illustrative example only: MLB-261124-0047 can represent branch code MLB, date 24 November 2026, and the 47th sample of the day. No matter what the format of the sample number is, there will be no reuse of sample numbers. If a sample number is used more than once, then a result for one person may be linked to another person's record.

Sample Registration vs Sample Receiving vs Sample Accessioning

Labs use these words loosely, and terminology differs between organizations. A common way to separate them: organizations.

ActivityPurposeTypical stage
Sample registrationCapture patient, doctor and test details and create the bill or orderFront desk, before or at collection
Sample receivingConfirm a physical sample has reached the labHandover from patient, phlebotomist or courier
Sample accessioningVerify the sample, accept or reject it and give it a unique identity in the recordImmediately after receiving, before testing

In a small lab all three may happen at one counter in a few minutes. In a hub-and-spoke network they are often separate steps done at different places.

Common Sample Accessioning Errors and How to Prevent Them

ErrorPractical prevention
Incorrect patient identificationRequire two identifiers on tube and requisition; reject or escalate mismatches
Mislabeled samplesLabel at the bedside or in front of the patient; one label printed at a time
Duplicate registrationsSearch by phone or patient ID before creating a new record
Missing patient or test informationMake key fields mandatory in the system
Incorrect specimen typeKeep a test-to-container chart at the receiving desk
Insufficient quantityDefine minimum volumes per test and check before accepting
Delayed registrationSet a maximum time from arrival to registration and monitor it
Wrong barcode attachmentScan the tube against the order before sending it onward
Incorrect test assignmentReview mapping of profiles and packages; double-check urgent orders
Poor coordination between centresShare one collection checklist and a daily dispatch list

Our guide on reducing sample rejection rates goes deeper on rejection causes.

Manual vs Automated Sample Accessioning

AreaManualAutomated (LIS-supported)
Data entryHandwritten registers or retypingEntered once in the system
Accession numberWritten or counted by handGenerated by configured rules
Barcode creationPre-printed or handwritten labelsPrinted on demand
Sample identificationVisual matching of namesBarcode scan plus visual check
Error preventionDepends on staff attentionMandatory fields, duplicate checks
Sample trackingAsking colleagues, searching racksStatus visible on screen
Staff workloadHigh at rush hoursLess repeated typing
Multi-branch coordinationCalls and messagesShared records across branches
Reporting and traceabilityReconstructed from registersTime-stamped history

Automation supports staff; it does not replace them. Someone must still look at the tube, judge its condition and decide whether to accept it. Barcodes reduce transcription mistakes but cannot catch a label stuck on the wrong tube.

How LIS Software Automates Sample Accessioning

accession. A properly set up LIS can take over most of the administrative work involved with accessioning, including digital registration, assigning unique accession numbers to each sample, printing labels and barcodes for samples, mapping tests, providing updates on status, routing samples to different departments, allowing centralized viewing of sample information throughout various locations, and connecting to analyzers. The overview we provide regarding LIS, LIMS, and the entire testing workflow provides a larger perspective on this topic.

From its public site, MargLabz identifies numerous functions related to this workflow: barcoded sample tracking from collection to archive, barcode printing, test master/catalogue management, home collection by a phlebotomist via routing, HL7/ASTM two-way analyzer interface, auto-validation using delta checks, multi-branch management, and outsourced testing management. For examples of how these functions are utilized in practice, refer to our previous articles on barcode sample tracking and outsourcing tests.

The features of the plans and the laboratory configurations will be different therefore you should check out the exact features during a demonstration. Bring with you your actual accession flow and ask about how accession numbers are generated, how labels are printed, and what happens when a rejected specimen is recorded.

Best Practices for Efficient Sample Accessioning

  • Standardize sample identification, using two identifiers on every tube.
  • In your SOP, you will write the acceptance and rejection criteria for each specimen type and test based upon your methods, specimen requirements, and relevant guidelines.
  • Train receiving and registration staff, and retrain after errors.
  • Use barcode identification where it fits your volume and budget.
  • Verify patient and test information against the requisition.
  • Keep one consistent accession-number rule across branches.
  • Record the receipt time of every sample.
  • Define how exceptions are handled, including who calls the collection center.
  • Monitor the time from when a patient arrives at your clinic until they are registered for their test, then monitor the time from registration to testing. To assist you with these daily operational tasks in the laboratory, please refer to our guide to daily operations in the laboratory.
  • Review accessioning errors every month and fix their causes.

Conclusion

Sample accessioning accuracy is the foundation for all future results being reliable. Once we verify the identity of the sample, write down the criteria for acceptance, assign a unique number to each sample, and record its entire travel history, then the laboratory has the ability to trace each result back to the specific tube that produced it. The use of barcodes and an adequately configured LIS will increase efficiency and consistency in this process; however, these tools will perform better when utilized by properly trained personnel and supported by a well-defined SOP.

If you would like to see how MargLabz can help manage the sample flow into and out of your lab, please review your current process for receiving and tracking samples.

Make Your Laboratory Workflows Smarter with MargLabz. Book a Free Demo

Book a Free Demo Today

Frequently asked

What is sample accessioning in a laboratory?

It is the process of receiving a specimen, verifying its identity and condition, registering it and assigning a unique accession number so it can be traced through testing and reporting.

What is the purpose of sample accessioning?

Its purpose is to give every sample a reliable identity and a record from the moment it arrives, so results can be linked to the correct patient and the sample's journey can be reviewed.

What is a sample accession number?

It is a unique identifier given to each received sample. It differs from the patient ID and the bill or order number, and its format depends on the laboratory and software.

Is sample accessioning the same as sample registration?

Not always. Registration usually captures patient and order details, often at the front desk. Accessioning verifies the physical sample and gives it a unique identity. Some labs combine both steps, and terms vary.

What are the main steps in sample accessioning?

Receipt, identity check, matching with the requisition, condition and quantity check, acceptance or rejection, registration, accession number and label, test and priority assignment, routing and status updates.

What information is required during sample accessioning?

Typically patient identifiers, sample type, collection and receipt time, requested tests, source branch or doctor, priority and sample condition. Your SOP and accreditation requirements decide the exact list.

How does barcode scanning improve sample accessioning?

Scanning links a tube to its record without retyping, which reduces transcription errors and speeds up registration and tracking. It does not remove the need to check that the label is on the right tube.

Can LIS software automate sample accessioning?

Yes. A configured LIS can generate accession numbers, print labels, assign tests and update status. Staff still verify identity and condition before accepting a sample.

How can diagnostic laboratories reduce sample accessioning errors?

Use two identifiers, written acceptance criteria, trained staff, barcode scanning, mandatory fields, duplicate checks and a monthly review of errors and their causes.