On Monday at 8:30 in the morning, a courier arrives at the reference lab of a city with a package containing samples collected from five different collection sites. Some of these samples have printed bar codes; others have names written by hand. One requisition is so badly smudged that it cannot be read. What happens to the samples in the next 20 minutes will determine if the patients receive the correct report on time. This initial step of processing the samples is called "sample accessioning".
Mistakes committed in this area seldom remain at the reception desk. An incorrect patient identification, a missing test, or a tube that has been entered one hour after being received will travel with the sample into the analytical instrument and ultimately onto the final report. This document describes what sample accessioning is, how the procedure occurs on a step-by-step basis, the purpose of an accession number, and how laboratory software assists.
What Is Sample Accessioning?
Sample accessioning involves the receipt of a specimen, verification of both identity and condition of the specimen, recording the specimen into the laboratory's record system, and providing the specimen with a unique identification number (accession number) for tracking during the testing and reporting processes.
In reality, accessioning connects two separate entities that must remain connected: the physical sample (tube) and the electronic record of the sample. All subsequent steps in the process, including the creation of a work list, the analysis of the sample, and the signing off on a report, depend upon this connection. Without being able to confidently match each individual tube with a single patient, a single order, and a single record, then regardless of how accurate or precise the testing may have been, the laboratory will not be able to justify or support the validity of the results.
Why Is Sample Accessioning Important in Diagnostic Laboratories?
The accessioning process is the initial step for a laboratory to formally check off the sample being processed and therefore provides an additional layer of security for all subsequent processes.
- Correct patient identification: you must correctly associate the correct patient with the correct tube prior to beginning the test.
- Fewer registration mistakes (errors): the cost of correcting those made at the time of entry can be reduced significantly. Mistakes in matching tubes with requisitions, and bills with either or both, can be identified before they become costly to correct.
- Traceability: Every single sample is documented with a chronological record of who accepted it, at what time, and what state it was in.
- Samples are routed directly to hematology, biochemistry, or microbiology without the need for searching.
- The recorded receipt time will show you when there are delays. For example, CDC's guidelines for the CLIA quality system require that all laboratory facilities record the date and time each specimen is received.
- The use of a single standard for receiving and processing each branch and franchise's intake procedures provides all branches and franchises with consistent guidelines.
- Accountability: Every time someone accepts or rejects a document, there is an individual with a name and a date/time stamp associated with that decision.
How Does the Sample Accessioning Process Work? Step by Step
Eleven steps are included in a proper workflow, although each laboratory has a slightly different order.
- Sample receipt. A receipt is provided for samples received by the laboratory. Laboratory staff collect samples from patients who visit the laboratory, home collection phlebotomists who have collected samples at patient homes, and sample collection boxes delivered to the laboratory via couriers. Errors include samples being left in a box without being logged.
- Identity Verification. Validate that the name, age or some other identification value listed on the tube matches what is displayed in either the requisition or bill. The CDC has provided guidance regarding CLIA-regulated testing and states that there should be at least two forms of patient identification listed on each sample. Example: A label that contains only the patient's first name.
- Match with the requisition. Verify that each tube is ordered and that all of those tubes are included in that order. Error: there are either too many or not enough tubes for a profile.
- Check your samples for the proper container, type of sample, amount, and quality. Do you have serum in a standard blood tube, or do you have EDTA blood for a complete blood count (CBC)? Is there a sufficient quantity of the sample and does it show signs of being hemolyzed or leaking? Error: The correct container was not used for the requested test.
- The next step is to apply the acceptance/rejection criteria. Then, compare the sample you have collected with your written standard operating procedures (SOP). The Centers for Disease Control and Prevention (CDC) list many of the most common reasons why samples may be rejected, including leakage, an inadequate quantity of material, collecting the wrong type of sample, labeling the sample incorrectly, storing/transporting the sample at the incorrect temperature, and experiencing delays in transporting the sample. Error: Accepting a questionable sample "just this once".
- Register the sample in the computer system. At that time, enter the date/time received, the originating branch/physician's office, and other relevant information about the sample into the laboratory information system (LIS) or registration document. Delay in registering the sample results in an inaccurate representation of the turnaround time.
- Create a distinct accession number. The system, or a controlled log, provides the number. Error: two samples have been given the same number.
- The barcode label can be printed or attached. It must go onto the proper tube. Error: The correct label was placed on the wrong tube.
- Assigning tests and priorities. as well as linking requested tests to the order, indicating if a sample is "STAT" or urgent, and noting whether it requires a fast or a timed collection. An error occurred when a package was ordered, however, one of the components within that package was not mapped.
- Route to the department. Send the tube to the correct bench, referral queue, or an outsourced partner. Error: a sample that arrives at the incorrect department.
- Maintain current status and follow the path of your samples. All movements of a sample will be documented for anyone who wishes to determine its location. However, if you update the status of your sample too late or do not update it at all, this is an error.
Receiving personnel or a designated accessioner typically perform steps one through eight of the process; however, if there are exceptions, they are processed by a senior technologist. The division of work will vary based on the size of the laboratory.
What Is a Sample Accession Number?
A typical example of an accession number is a unique identification code that laboratories assign to incoming specimens to allow for easy identification of the specimen's records, to track each individual specimen, and to prevent confusion between different specimens.
Each patient's unique identification number (which is assigned when a patient first receives care) remains associated with the individual regardless of how many times they receive care. Each order/bill has a separate unique identification number that applies to only one visit. One order may result in multiple tubes, each of which will have a unique sample ID/accession number. The format of the unique identification number varies based on what type of laboratory is using it and how its computer systems are configured. Some laboratories utilize consecutive numbering, while others utilize the date of service and/or location of the facility as part of the unique identification number.
Illustrative example only: MLB-261124-0047 can represent branch code MLB, date 24 November 2026, and the 47th sample of the day. No matter what the format of the sample number is, there will be no reuse of sample numbers. If a sample number is used more than once, then a result for one person may be linked to another person's record.
Sample Registration vs Sample Receiving vs Sample Accessioning
Labs use these words loosely, and terminology differs between organizations. A common way to separate them: organizations.
| Activity | Purpose | Typical stage |
|---|---|---|
| Sample registration | Capture patient, doctor and test details and create the bill or order | Front desk, before or at collection |
| Sample receiving | Confirm a physical sample has reached the lab | Handover from patient, phlebotomist or courier |
| Sample accessioning | Verify the sample, accept or reject it and give it a unique identity in the record | Immediately after receiving, before testing |
In a small lab all three may happen at one counter in a few minutes. In a hub-and-spoke network they are often separate steps done at different places.
Common Sample Accessioning Errors and How to Prevent Them
| Error | Practical prevention |
|---|---|
| Incorrect patient identification | Require two identifiers on tube and requisition; reject or escalate mismatches |
| Mislabeled samples | Label at the bedside or in front of the patient; one label printed at a time |
| Duplicate registrations | Search by phone or patient ID before creating a new record |
| Missing patient or test information | Make key fields mandatory in the system |
| Incorrect specimen type | Keep a test-to-container chart at the receiving desk |
| Insufficient quantity | Define minimum volumes per test and check before accepting |
| Delayed registration | Set a maximum time from arrival to registration and monitor it |
| Wrong barcode attachment | Scan the tube against the order before sending it onward |
| Incorrect test assignment | Review mapping of profiles and packages; double-check urgent orders |
| Poor coordination between centres | Share one collection checklist and a daily dispatch list |
Our guide on reducing sample rejection rates goes deeper on rejection causes.
Manual vs Automated Sample Accessioning
| Area | Manual | Automated (LIS-supported) |
|---|---|---|
| Data entry | Handwritten registers or retyping | Entered once in the system |
| Accession number | Written or counted by hand | Generated by configured rules |
| Barcode creation | Pre-printed or handwritten labels | Printed on demand |
| Sample identification | Visual matching of names | Barcode scan plus visual check |
| Error prevention | Depends on staff attention | Mandatory fields, duplicate checks |
| Sample tracking | Asking colleagues, searching racks | Status visible on screen |
| Staff workload | High at rush hours | Less repeated typing |
| Multi-branch coordination | Calls and messages | Shared records across branches |
| Reporting and traceability | Reconstructed from registers | Time-stamped history |
Automation supports staff; it does not replace them. Someone must still look at the tube, judge its condition and decide whether to accept it. Barcodes reduce transcription mistakes but cannot catch a label stuck on the wrong tube.
How LIS Software Automates Sample Accessioning
accession. A properly set up LIS can take over most of the administrative work involved with accessioning, including digital registration, assigning unique accession numbers to each sample, printing labels and barcodes for samples, mapping tests, providing updates on status, routing samples to different departments, allowing centralized viewing of sample information throughout various locations, and connecting to analyzers. The overview we provide regarding LIS, LIMS, and the entire testing workflow provides a larger perspective on this topic.
From its public site, MargLabz identifies numerous functions related to this workflow: barcoded sample tracking from collection to archive, barcode printing, test master/catalogue management, home collection by a phlebotomist via routing, HL7/ASTM two-way analyzer interface, auto-validation using delta checks, multi-branch management, and outsourced testing management. For examples of how these functions are utilized in practice, refer to our previous articles on barcode sample tracking and outsourcing tests.
The features of the plans and the laboratory configurations will be different therefore you should check out the exact features during a demonstration. Bring with you your actual accession flow and ask about how accession numbers are generated, how labels are printed, and what happens when a rejected specimen is recorded.
Best Practices for Efficient Sample Accessioning
- Standardize sample identification, using two identifiers on every tube.
- In your SOP, you will write the acceptance and rejection criteria for each specimen type and test based upon your methods, specimen requirements, and relevant guidelines.
- Train receiving and registration staff, and retrain after errors.
- Use barcode identification where it fits your volume and budget.
- Verify patient and test information against the requisition.
- Keep one consistent accession-number rule across branches.
- Record the receipt time of every sample.
- Define how exceptions are handled, including who calls the collection center.
- Monitor the time from when a patient arrives at your clinic until they are registered for their test, then monitor the time from registration to testing. To assist you with these daily operational tasks in the laboratory, please refer to our guide to daily operations in the laboratory.
- Review accessioning errors every month and fix their causes.
Conclusion
Sample accessioning accuracy is the foundation for all future results being reliable. Once we verify the identity of the sample, write down the criteria for acceptance, assign a unique number to each sample, and record its entire travel history, then the laboratory has the ability to trace each result back to the specific tube that produced it. The use of barcodes and an adequately configured LIS will increase efficiency and consistency in this process; however, these tools will perform better when utilized by properly trained personnel and supported by a well-defined SOP.
If you would like to see how MargLabz can help manage the sample flow into and out of your lab, please review your current process for receiving and tracking samples.
Make Your Laboratory Workflows Smarter with MargLabz. Book a Free Demo